What laboratory studies suggest
CO₂ around respiratory particles may affect droplet chemistry and the rate at which SARS-CoV-2 loses infectivity after exhalation.
Big news: New case study: TEMA Fine Foods — energy label G → C, time above 800 ppm cut from 13% to 0.02%
A modelled result and a measured result are not the same thing, and we do not present them as though they were. This page explains how we label evidence, how we verify performance, and who we work with.
Engineering calculation for high-occupancy buildings with long operating hours. Actual result depends on occupancy, climate, HVAC configuration and current performance.
Engineering calculation of outdoor-air volume required to hold the same CO₂ target with Clever Air Care in operation.
Hard control floor enforced by the Maxairea controller. Ventilation is never reduced below this level.
Installed in the technical room, into an existing air-handling unit. Demonstrated at TEMA Fine Food and SPIE.
In 2026, TNO reviewed a number of scientific publications for Maxairea on the potential relationship between indoor CO₂ concentrations and the infectivity of SARS-CoV-2 in aerosols. The key findings and referenced scientific sources are summarised in the accompanying reports.
CO₂ around respiratory particles may affect droplet chemistry and the rate at which SARS-CoV-2 loses infectivity after exhalation.
Particle size, relative humidity, trace gases and real-building conditions can change the same chemistry and may weaken, strengthen or reverse the observed effect.
The possible effect is a testable research question requiring independent validation. It is not a demonstrated infection-control benefit in occupied buildings.
Ventilation and particle removal remain the core controls for airborne exposure. CO₂ should not be used on its own as proof of a high ventilation rate or as an infection-safety threshold.
Before anything is installed we measure CO₂ concentration, airflow and HVAC energy consumption under normal operation. That baseline is the reference for every later claim.
Occupancy, operating hours, ventilation design and climate feed an engineering calculation of achievable outdoor-air and energy reduction for your building — not a generic figure.
After commissioning, the same parameters are measured again over a representative period and compared against the baseline.
Where a project supports it, results are reviewed with research and engineering partners before publication.
Maxairea develops and demonstrates Clever Air Care with research institutes, building-services contractors and controls specialists working on live installations.
Challenge: ventilation relied largely on windows, with inconsistent indoor air quality and high energy demand (label G, 643 kWh/m²·yr). Solution: room sensors, mechanical ventilation, heat recovery, Maxairea CO₂ filtration and radiator control connected through one intelligent automation layer, with smart control developed with MESH Building Management Solutions. Result: measured data show building-wide P95 CO₂ fell from 942 to 671 ppm (A/B commissioning comparison) and time above 800 ppm from 13.24% to 0.02%, while the official energy label improved from G to C and energy use fell to 224.86 kWh/m²·yr.
The Maxairea Clever Air Care System was added to an existing air-handling unit to improve indoor air quality and reduce energy consumption. Initial results indicate a strong positive impact on IAQ, HVAC energy use, and total cost of ownership. Full results to be announced with the SPIE Netherlands team.
The Maxairea Clever Air Care System is integrated into the Office Lab’s air-handling unit at The Green Village, TU Delft Campus. By removing CO₂ from incoming outdoor air, the system aims to reduce the ventilation air that needs to be heated or cooled. This demonstration investigates whether Class A indoor air quality can be maintained with less ventilation air. Monitoring covers CO₂ and other air-quality parameters, alongside an evaluation of energy savings. Project-specific performance results have not been published on The Green Village’s project page.
Nelissen Engineering has incorporated Maxairea’s CO₂ capture technology into the Bisonspoor Police Station design. By treating CO₂ directly, the concept enables approximately 33% lower design airflow, smaller ducts and air-handling capacity, and an estimated 20 kW reduction in both heating and cooling capacity. The project shows Maxairea’s broader value: improving indoor air quality while reducing system size, energy demand and overall building-services costs from the design stage onward.
If you need to defend a saving to an auditor, asset manager or energy consultant, we will walk you through exactly how it is measured before you commit to anything.
A free assessment shows whether Maxairea suits your building, what outdoor-air reduction is realistic, and what installation involves — before you commit.